YOKOGAWA
The world’s smallest dual bent tube Coriolis Mass Flow and Density Meters series for highly accurate measurement at lowest flows.
The dual tube design compensates for fluctuations of density, temperature, pressure and environment conditions. This provides a consistent repeatable and accurate measurement especially for small size Coriolis Mass Flow and Density Meters
The versatile Coriolis Mass Flow and Density Meters with superior turndown and lowest pressure drop in the market. Ideal for a broad range of standard applications, this series is a flexible and cost effective solution for highly accurate flow and density measurements. Features such as concentration measurement or the Tube Health Check function allow the meter to be adjusted to customer needs.
Specifically designed and certified for food & beverage, biotechnology and pharmaceutical utility applications. (EHEDG certified, 3-A certified)
This series is the appropriate answer to the daily constraints of hygienic processes ensuring continuous product quality and minimizing losses. This is made easy by the provided multi-variable measurement and various dedicated features.
ADMAG AXG series Magnetic Flowmeter is a high-quality and highly reliable product developed based on years of experience and achievement, such as enhancement of application by our proprietary dual frequency excitation method.
Certified to SIL2 complied with functional safety standard IEC 61508, and can be used in safety instrumented systems up to SIL2 in simplex configuration and SIL3 in redundant configuration.
ADMAG AXG is ideal for industrial process lines like oil & gas / chemical / pulp & paper / food & beverage / metal & mining applications.
With outstanding reliability and ease of operation and maintenance, developed on decades of field-proven experience, ADMAG AXG will increase your benefits while reducing total cost of ownership.
Industries | Typical Line and Process | Typical Fluid |
---|---|---|
Chemical | – Polymerization process | – Strong acid fluid – Strong alkaline fluid – Permeable fluid |
Pulp & Paper | – Digester Circulation and Extraction Line – Blow Line – Bleach line – DIP |
– Black liquor – White liquor – Pulp slurry |
Food & Beverage | – Raw material blending process | – Retort food – Cream – CIP cleaning solution |
Power | – LNG vaporizer | – Various cooling water |
Iron & Steel | – Blast furnace tuyere | – Electric furnace dust collection water |
Vortex Flowmeter VY Series can measure the flow rates of liquids, gases, saturated steam, and superheated steam, and has self-diagnostic and remote maintenance functions. A choice of materials is available for the wetted parts, stainless steel including duplex stainless steel or nickel alloys. The series complies with a wide range of standards, including explosion-proof and SIL2. The current input function (HART7, when current input specification is selected) supports more accurate calculation capabilities* than ever before, including mass flow rate and energy flow rate of liquids, gases, and steam.
Model | ・DY type vortex flowmeter (Integral type, remote type detector) | |
・DYA type remote type converter | ||
Specification | Standard specification | |
Measurement Fluid | Liquid, gas, saturated steam, superheated steam (avoid multi-phase flow and adhesive fluid) | |
Process Temperature | -29 to 250 °C | |
Process Pressure | -0.1 MPa according to flange rating | |
Diameter | Wafer | 15 to 100 mm |
Flange | 15 to 400 mm | |
Accuracy | Liquid | ± 0.75 % of reading (depends on Reynolds number) |
Gas, Steam | ± 1.0 % of reading (depends on the flow velocity) | |
Output Signal | Analog output, transistor contact output (simultaneous output possible) | |
Communication Type | HART 7 / HART 5, BRAIN, FOUNDATION fieldbus | |
Explosion Protected Type | TIIS Ex d, FM Ex d / Ex ia, ATEX Ex db / Ex ia, CSA Ex d / Ex ia, IECEx Ex db / Ex ia |
The RAGN Rotameter is designed for continuous flow measurement of liquids and gases. The borosilicate glass metering tube has a brightly colored easy to read scale. The RAGN comes standard with in-line 316 stainless steel fittings and optional stainless steel, titanium, PTFE or PVDF internals. Connection fittings for the RAGN can be chosen from NPT thread or Flanged connections.
The fluid passes through the metering tube from bottom to top so vertical installation is required. The actual flow is indicated by the top of the float and can be directly read from the scale on the metering tube.
Process Connection Diameter ØD | Dimension L | Process Connection Flanged “L” Dimension |
---|---|---|
1/2 inch | 375 mm / 14.7 inches | 475 mm / 18.7 inches |
3/4 inch | 375 mm / 14.7 inches | 475 mm / 18.7 inches |
1 inch | 375 mm / 14.7 inches | 475 mm / 18.7 inches |
1 1/2 inches | 375 mm / 14.7 inches | 475 mm / 18.7 inches |
2 inches | 375 mm / 14.7 inches | 475 mm / 18.7 inches |
2 1/2 inches | 375 mm / 14.7 inches | 475 mm / 18.7 inches |
At first glance, the instrument looks impressive with its all stainless steel design. A closer look reveals a “float blockage” detection system. Operational safety is of the utmost importance in any flowmeter, and the RAMC is no exception – wetted parts are available in a variety of materials, and intrinsically safe outputs are available as an option.
If you value flexibility in a flowmeter – from the measurement of air to highly aggressive liquids – in situ replacement of the indicator without loss of performance – and the interchangeability of floats – then the RAMC is the right choice for you.
The RAMC combines all the advantages of the variable area principle with robust design, reliable measurement, with or without power, HART, culminating in a truly universal flowmeter for gases, liquids and steam applications.
Process Connection Diameter | Flanged Process Connection Dimension ” L “ | NPT Process Connection Dimension ” L “ |
---|---|---|
1/2 inch | 250 mm / 9.8 inches | 295 mm / 11.6 inches |
3/4 inch | 250 mm / 9.8 inches | 295 mm / 11.6 inches |
1 inch | 250 mm / 9.8 inches | 295 mm / 11.6 inches |
1 1/4 inches | 250 mm / 9.8 inches | 295 mm / 11.6 inches |
1 1/2 inches | 250 mm / 9.8 inches | 295 mm / 11.6 inches |
2 inches | 250 mm / 9.8 inches | 310 mm / 12.2 inches |
2 1/2 inches | 250 mm / 9.8 inches | 325 mm / 12.7 inches |
3 inches | 250 mm / 9.8 inches | 325 mm / 12.7 inches |
3 1/2 inches | 250 mm / 9.8 inches | N/A |
4 inches | 250 mm / 9.8 inches | N/A |
5 inches | 250 mm / 9.8 inches | N/A |
6 inches | 260 mm / 10.2 inches | N/A |
Part | Standard | Optional |
---|---|---|
Flanges | Stainless Steel | Titanium, Hastelloy, Monel |
Threads NPT | Stainless Steel | Titanium, Hastelloy, Monel |
Metering Tube | Stainless Steel | Titanium, Hastelloy, Monel, PTFE Coated |
Float | Stainless Steel | Titanium, Hastelloy, Monel, PTFE Coated |
Indicator Housing | Stainless Steel / Aluminum | Epoxy coating, High Anti Corrosion Coating |