See-Flo® 3100
Description:
See-Flo® sight flow indicators show you at a glance, the color, clarity and flow of liquids in process lines. The large tempered glass window permits easy observation of fluid conditions and vane indicator position. The wedge shape of the meter housing makes See-Flo® practically self-cleaning. Where periodic maintenance might be necessary, the window is easily removed and replaced. As this is a sight flow indicator, it does not include a calibrated scale.
Features:
- Observe fluid conditions for color, clarity and flow.
- Repeatable vane indication-same position at same flow rate.
- This enables the user to mark a normal condition on the ledge below the pointer.
- Use in horizontal or vertical piping systems.
- Low pressure loss.
- Simple design with few parts for long service life.
Material of Construction (wetted parts)
- Housing: aluminum, brass or 316 stainless steel
- Shunt: housing material or carbon steel
- Window: tempered glass Vane: 17-7 ph stainless steel.
- “O” Rings: buna-n, ethylene propylene, Viton® or perfluoroelastomer M Piping.
Connections
- 1/2” to 1″ NPT Female
- 1 1/4” to 4″ NPT Male
- 1/2” to 3″ Tri-clamp
- 1 1/4” to 6″ Grooved
- 1 1/4” to 6″ Beveled
- 1/2” to 6″ 150#/300# RF/FF ANSI Flanges (carbon stl)
- 1/2” to 6″ 150# RF ANSI Flanges (stainless steel)
- 1/2” to 6″ 150#/300# RF ANSI Flanges (aluminum)
- 1/2” to 6″ 150# FF ANSI Flanges (brass)
- 15 to 25 mm DIN 2999/BS21/ISO R7 Female threaded
- 15 to 150 mm DIN PN 10 Flanges (316 stainless stl & carbon stl)
Reference:
See-Flo® 3200
Description:
See-Flo® Meters indicate flow rate and permit visual inspection of water, air or other transparent fluids. For general purpose industrial service, See-Flo® meters handle a wide range of process fluids in vertical or horizontal piping runs. The wedge shape of the meter housing makes See-Flo® practically self-cleaning. Where periodic maintenance might be necessary, the tempered glass window is easily removed and replaced.
Features:
- Instantaneous flow rate measurement.
- Observe fluid conditions for color, clarity and flow.
- Use in horizontal or vertical piping systems.
- Individually calibrated for fluid and operating conditions.
- User selectable 10:1 turndown flow ranges. (See Meter Rangeability Sizing Tables)
- User selectable units of measure including dual units of measure.
- No floats to get stuck, tubes to break or dynamic seals to leak.
- Low pressure loss.
- Simple design with few parts for long service life.
Material of Construction
- Housing: Aluminum,brass, 70/30 copper/nickel, 316 stainless steel.
- Shunt: As housing or carbon steel.
- Window: Tempered glass or polycarbonate.
- Vane: Cobalt/chromium/nickel alloy with Teflon ® encapsulated magnet.
- “O” rings: buna-n, ethylene propylene, Viton® or perfluoroelastomer.
Connections
- 1⁄2″ to 1″ NPT Female
- 1 1⁄4″ to 4″ NPT male
- 1 1⁄2″ to 3″ Tri-clamp
- 1 1⁄4″ to 6″ Grooved
- 1 1⁄4″ to 6″ Beveled 1⁄2″ to 8″ 150# /300# RF/FF ANSI Flanges (carbon stl)
- 1⁄2″ to 8″ 150# RF ANSI Flanges (stainless stl)
- 1⁄2″ to 6″ 150# RF ANSI Flanges (aluminum)
- 1⁄2″ to 6″ 150# FF ANSI Flanges (brass)
- 15 to 25 mm DIN 2999/BS21/ISO R7 Female threaded
- 15 to 150 mm DIN PN 10 Flanges (316 stainless stl & carbon stl)
Reference:
Armor-FloTM 3400
Description:
Measure liquid, gas or steam flow rates in horizontal or vertical pipelines. Armor-FloTM meters handle fluids that cannot be measured with the See-Flo® due to clarity, pressure or compatibility with wetted materials. The wedge shape of the meter body housing provides the Armor-FloTM with the same self-cleaning characteristics as the See-Flo®. Teflon® encapsulated cobalt magnets are used to couple the flow isolated indicator with the vane. These features emphasize simplicity and reduce maintenance.
Features:
- Instantaneous rate measurement.
- Measure opaque fluids.
- More exotic materials of construction.
- Use in horizontal or vertical piping systems.
- Individually calibrated for fluid and operating conditions.
- User selectable 10:1 turndown flow ranges. (See “Meter Rangeability Sizing Tables”)
- User selectable units of measure-including dual units of measure.
- No floats to get stuck, tubes to break or dynamic seals to leak.
- Low pressure loss.
- Simple design with few parts for long service life.
Material of construction
- Housing: Aluminum,brass, 70/30 copper/nickel, 316 stainless steel
- Shunt: As housing or carbon steel
- Window: Tempered glass or polycarbonate
- Vane: Cobalt/chromium/nickel alloy with Teflon ® encapsulated magnet
- “O” rings: buna-n, ethylene propylene, Viton® or perfluoroelastomer.
Connections
- 1/2” to 1″ NPT Female
- 1 1/4” to 4″ NPT male
- 1 1/2” to 3″ Tri-clamp
- 1 1/4” to 6″ Grooved
- 1 1/4” to 6″ Beveled
- 1/2” to 8″ 150# /300# RF/FF ANSI Flanges (carbon stl)
- 1/2” to 8″ 150# RF ANSI Flanges (stainless stl)
- 1/2” to 6″ 150# RF ANSI Flanges (aluminum)
- 1/2” to 6″ 150# FF ANSI Flanges (brass)
- 15 to 25 mm DIN 2999/BS21/ISO R7 Female threaded
- 15 to 150 mm DIN PN 10 Flanges (316 stainless stl & carbon stl)
Reference:
Armor-FloTM 3500
Description:
Armor-Flo 3500 meters provide even more effective process control input with switching capabilities. Simple electromechanical switches define your process limits. Adjustable switches provide positive indication of flow/no flow conditions and may be positioned to actuate at specific flow rates. The design of the switch is to capture the indicator, preventing movement until the flow rate is once again within the acceptable range. The switches are SPDT glass encapsulated reed type rated at 0.25 amperes at 120V ac (1.5 amperes at 24V dc). This switch is appropriate for use in Class 1, Division 2 areas.
Features:
- Instantaneous flow rate measurement.
- Adjustable low and/or high flow limit switches.
- Use in horizontal or vertical piping systems.
- Individually calibrated for fluid and operating conditions.
- User selectable 10:1 turndown flow ranges.
- User selectable units of measure.
- No floats to get stuck, tubes to break or dynamic seals to leak.
- Low pressure loss.
Switch/Type:
Hermetically sealed reed switch Contact rating: 0.25A @ 120 Vac 1.5A @ 24V dc
Adjustment limits: 20-50% full scale-low limit 50-90% full scale-high limit 30% differential between low and high
Dead Band: 7% full scale
Materials of Construction
- Housing: Aluminum, brass, 70/30 copper/nickel, 316 stainless steel.
- Shunt: As housing or carbon steel.
- Window: Tempered glass or polycarbonate.
- Vane: Cobalt/chromium/nickel alloy with Teflon ® encapsulated magnet
- “O” rings: buna-n, ethylene propylene, Viton® or perfluoroelastomer.
Piping Connections
- 1/2” to 1″ NPT female
- 1 1/4” to 4″ NPT male
- 1 1/2” to 3″ Tri-clamp
- 1 1/4” to 6″ Grooved
- 1 1/4” to 6″ Beveled
- 1/2” to 8″ 150# /300# RF/FF ANSI Flanges (carbon stl)
- 1/2” to 8″ 150# RF ANSI Flanges (stainless stl)
- 1/2” to 6″ 150# RF ANSI Flanges (aluminum)
- 1/2” to 6″ 150# FF ANSI Flanges (brass)
- 15 to 25 mm DIN 2999/BS21/ISO R7 Female threaded
- 15 to 150 mm DIN PN 10 Flanges (316 stainless stl & carbon stl)
Reference:
Armor-FloTM 3600
Description:
Armor-FloTM meters with integral transmitters provide an ideal combination – a local mechanical flow rate indicator independent of electrical supply with a 4-20 mA two wire loop powered signal output. The output signal is linear within the middle 80% of the range. A response curve is furnished with each flowmeter. Simple design, rugged construction and good value make this the ideal utility fluid flowmeter.
Features:
- Instantaneous local flow rate measurement.
- Local flow rate indication requires no power.
- Flow proportional signal output.
- Broad range of materials available.
- Use in horizontal or vertical piping systems.
- Individually calibrated for fluid and operating conditions.
- User selectable 10:1 turndown flow ranges. (“See Meter Rangeability Sizing Tables”)
- User selectable units of measure-including dual units of measure.
- No floats to get stuck, tubes to break or dynamic seals to leak.
- Low pressure loss.
- Simple design with few parts for long service life.
Transmitter
Accuracy: ± 2% full scale Repeatability: ± 0.5% full scale Permissible load: Rmax= 750 Ω Temperature limits: 0-85°C (32-185°F) Environmental: NEMA 4/NEMA 4x
Material of construction
- Housing: Aluminum, brass, 316 stainless steel
- Shunt: As housing or carbon steel
- Window: Tempered glass or polycarbonate
- Vane: Cobalt/chromium/nickel alloy with Teflon® encapsulated magnet
- “O” rings: Buna-n, ethylene propylene, Viton® or perfluoroelastomer.
Pipe connections
- 1/2” to 1″ NPT Female
- 1 1/4” to 4″ NPT male
- 1 1/2” to 3″ Tri-clamp
- 1 1/4” to 6″Grooved
- 1 1/4” to 6″ Beveled
- 1/2” to 8″ 150# /300# RF/FF ANSI Flanges (carbon stl)
- 1/2” to 8″ 150# RF ANSI Flanges (stainless stl)
- 1/2” to 6″ 150# RF ANSI Flanges (aluminum)
- 1/2” to 6″ 150# FF ANSI Flanges (brass)
- 15 to 25 mm DIN 2999/BS21/ISO R7 Female threaded
- 15 to 150 mm DIN PN 10 Flanges (316 stainless stl & carbon stl)
Reference:
Armor-FloTM 3700
Description:
The 3700 Series meter measures the flow rate of liquid, gas or steam in vertical or horizontal pipelines. In addition, it provides flow proportional signal outputs as well as switch options in an electrical enclosure appropriate for use in Class 1, Division 1, Groups C & D areas. Even without power, the flow rate indicator functions. Features UL Listed enclosure. Low pressure loss. Install in horizontal or vertical pipe systems. Local flow rate indicator operates without power. Direct reading, each instrument is individually calibrated for the operating conditions specified. Available with signal and switch options.
Signal output options
- 4-20 mA two wire loop powered transmitter.
- 4-20 mA transmitter with two adjustable set points.
- Low flow limit switch. Adjustable 20-50% of full scale. SPDT contacts rated 0.25 A @ 120V ac/1.5 A @ 24V dc.
- High flow limit switch. Adjustable 50-90% of full scale. SPDT contacts rated 0.25 A @ 120V ac/1.5 A @ 24V dc.
- Low and high flow limit switches. There must be a 30% of full scale differential between low and high switch settings. SPDT contact rated 0.25 A @ 120V ac/ 1.5 A @ 24V dc.
Reference: