Type 8041 – Insertion Electromagnetic Inductive Flowmeter.

 

Description:

The electromagnetic flowmeter 8041 is made up of an electronic module and a sensor consisting of PVDF or stainless steel material. It has been designed to measure a flow rate of neutral and slightly aggressive fluids with a conductivity of more than 20 µS/cm in DN 06…DN 400 pipes. It is fitted with a 4…20 mA output, a pulse output and a relay output. The different parameters can be set by means of 5 DIP switches, a push-button and a 10-field LED bar graph. This flowmeter is available either with a G 2″ connection with a PVDF sensor or, a G 2″ or clamp connection with a stainless steel sensor which are designed for use with Type S020 Insertion fitting. The variant with a stainless steel sensor can be used in applications with higher pressures (PN 16) and higher temperatures (150 °C).

 

Features:
  • Sensor without moving parts
  • Flowmeter with On/Off control
  • Application related calibration by Teach-In function
  • Clean in place (CIP)
  • FDA-compliant materials

 

Interfacing Devices:

 

Reference:

Type 8045 – Insertion Electromagnetic Inductive Flowmeter.

 

Description:

The electromagnetic flowmeter 8045 is made up of an electronic module including a backlit display, operating keys and a sensor consisting of PVDF or stainless steel material. It has been designed to measure a flow rate of neutral and slightly aggressive fluids with a conductivity of more than 20 µS/cm in DN 06…DN 400 pipes. It is equipped with a 4…20 mA output, a digital output (pulse output by default). Some versions are equipped with two relay outputs and one digital input. Two independent totalizers allow counting the flow rate. The available process connections are: – G2” connection for the version with a PVDF sensor – G2” or clamp connection for the version with a stainless steel sensor. The version with a stainless steel sensor can be used in applications with higher pressures (PN 16) and higher temperatures (110 °C). The version with Alloy C22 electrodes has been designed for applications with aggressive fluids (chemicals) and especially sea water applications.

 

Features:
  • Sensor without moving parts
  • Indicates both flow rate and volume
  • Simulation of all output signals
  • Clean in place (CIP), FDA-compliant materials
  • Version with Alloy C22 electrodes.

 

Interfacing Devices:

 

Reference:

 

Type 8050 In-line Electromagnetic-Inductive Flowmeter.

 

Description:

The Type 8050 is a compact magnetic-inductive flow measuring device that will help you monitor your processes. Thanks to its compact and robust design, this device is the perfect solution for applications where space needs to be saved. Additional connection adapters enable smooth integration into the process and the wireless connection facilitates starting up the device.

 

Features:
  • For continuous multiparameter monitoring
  • Measuring and monitoring of flow, temperature and conductivity
  • Quick and flexible start-up via IO-Link and wireless short-distance communication via radio waves
  • Easy adjustment to suit the process by using adapters.

 

Interfacing Devices:

 

Reference:

Type S051 – Magnetic inductive flow sensor, low flow rates.

 

Description:

The Type S051 magnetically inductive flow sensor (compact or separate version) is suitable for low-flow applications and liquids with minimum conductivity. The combination with the dedicated SE58 S transmitter (minimum required conductivity: 20 µS/cm) or with the SE58 M or SE58 L transmitters (minimum conductivity required: 5 µS/cm) results in a flowmeter with different performance, functions, materials and approvals, with the corresponding suitability for the respective applications depending on the respective requirements. With the SE58 S you get a compact device, with the SE58 M and SE58 L compact devices or remote versions are created for which the transmitter and sensor are connected by 2 cables up to a maximum length. Standard process connections available for the S051 are thread connections in G or NPT.

 

Features:
  • For connection to a Type SE58 transmitter (with or without display, in compact or remote version) for flow measurement
  • Clean in place (CIP) capable
  • Flow rate measurements 0.2…approx. 200 l/min for DN 03…DN 20.

 

Interfacing Device:

 

Reference:

Type S054 magnetically inductive flow sensor.

 

Description:

The Type S054 magnetically inductive flow sensor (compact or separate version) is suitable for liquids with a minimum conductivity and for use in applications with requirements in areas of water measurements. The combination with the dedicated SE58 S transmitter (minimum required conductivity: 20 µS/cm) or with the SE58 M or SE58 L transmitters (minimum conductivity required: 5 µS/cm) results in a flowmeter with different performance, functions, materials and approvals, with the corresponding suitability for the respective applications depending on the respective requirements. With the SE58 S you get a compact device, with the SE58 M and SE58 L compact devices or remote versions are created for which the transmitter and sensor are connected by 2 cables up to a maximum length. Standard process connections available for the S054 are wafer connections.

 

Features:
  • For connection to a transmitter Type SE58 (with or without display, in compact or remote version) for flow measurement
  • Design mainly for use in applications with water
  • Flow measurement 25…approx. 75,000 l/min for DN 25…DN 400.

 

Interfacing Device:

 

Reference:

Type S055 magnetically inductive flow sensor.

 

Description:

The Type S055 magnetically inductive flow sensor (compact or separate version) is suitable for liquids with a minimum conductivity and for use in applications with requirements in areas of water measurements. The combination with the dedicated SE58 S transmitter (minimum required conductivity: 20 µS/cm) or with the SE58 M or SE58 L transmitters (minimum conductivity required: 5 µS/cm) results in a flowmeter with different performance, functions, materials and approvals, with the corresponding suitability for the respective applications depending on the respective requirements. With the SE58 S you get a compact device, with the SE58 M and SE58 L compact devices or remote versions are created for which the transmitter and sensor are connected by 2 cables up to a maximum length. Standard process connections available for the S055 are flange connections.

 

Features:
  • For connection to a transmitter Type SE58 (with or without display, in compact or remote version) for flow measurement
  • Design mainly for use in applications with water
  • Flow measurement 25…approx. 75,000 l/min for DN 25…DN 400.

 

Interfacing Device:

 

Reference:

Type S056 – Magnetic inductive sensor with hygienic ­process connections.

 

Description:

The Type S056 magnetically inductive flow sensor (compact or separate version) is suitable for low-flow applications and liquids with minimum conductivity. The combination with the dedicated SE58 S transmitter (minimum required conductivity: 20 µS/cm) or with the SE58 M or SE58 L transmitters (minimum conductivity required: 5 µS/cm) results in a flowmeter with different performance, functions, materials and approvals, with the corresponding suitability for the respective applications depending on the respective requirements. With the SE58 S you get a compact device, with the SE58 M and SE58 L compact devices or remote versions are created for which the transmitter and sensor are connected by 2 cables up to a maximum length. Standard process connections available for the S056 are clamp or thread (dairy thread) connections.

 

Features:
  • For connection to a transmitter Type SE58 (with or without display, in compact or remote version) for flow measurement
  • Hygienic version, 3A certificate
  • For food and beverage or pharmaceutical applications
  • Flow rate measurements 0.2…approx 4,500 l/min for DN 03…DN 100.

 

Interfacing Device:

 

Reference:

Type SE58 – Transmitters for electromagnetic inductive flow sensors.

 

Description:

The Type SE58 transmitter (in S, M or L version) associated with the electromagnetic flow sensor (in compact or remote version) Type S051, S054, S055 or S056 is recommended for applications with a minimum conductivity of 5 μS/cm. SE58S: This variant of transmitter can only be used to build a compact version of a flowmeter, with or without a display. It is characterized by small external dimensions and: – for a version without display, by a case and a cover in black painted aluminum or stainless steel, – for a version with display, by a black painted aluminum or stainless steel case and by a plastic cover. The display is integrated in the lid. Flow and totalizer values are displayed simultaneously, as well as symbols for device status and alarms. The flow measurement can be transferred by a digital output or an analog output. The achievable uncertainty is 0.5% of the measured value. The device cannot be improved with the addition of input/output signals and functionalities such as dosing. SE58 M and SE58 L: These variants of transmitters, with painted aluminum, plastic or stainless steel housing, are available to build a compact or remote version of a flowmeter, with or without a display. It is possible to add input/output signals and to have all the functionalities, for example dosing (only SE58 L) and data logger. The human-machine interface (HMI), comprising the display and the control keys, allows the choice of flexible data presentations, the carrying out of complete settings and the configuration of the device. The L version is characterized by superior performance as shown by the low uncertainty of 0.2% of the measured value compared to 0.4% (option) and 0.8% with the M version.

 

Features:
  • Must be combined with sensor Type S051, S054, S055 or S056
  • Continuous measurement, high accuracy
  • Different housing shapes and materials available
  • Compact and remote design selectable, available with or without display.

 

Reference:

Type 8077 – Flowmeter with oval rotors.

 

Description:

This sensor is specially designed for measurement or batch control of highly viscous fluids like glue, honey or oil. It allows an easy connection to transmitters like types 8025, 8611 and 8619 for more functionality. The design of this low flow sensor is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of this design. The low pressure drop and high pressure rating make it suitable for gravity and pump (in-line) applications and many others. All sensors provide Open Collector NPN frequency output and frequency output on Reed contact via 1-meter 5-wire cable.

 

Features:
  • For highly viscous fluids
  • Value indication, monitoring, transmitting, On/Off control and batch control in combination with different transmitters.

Interfacing Devices:

 

Reference:

Type 8071 – Oval rotor low flow sensor.

 

Description:

This sensor is specially designed for measurement or batch control of highly viscous fluids like glue, honey or oil. It allows an easy connection to transmitters like types 8025 and 8619 for more functionality. The design of this low flow sensor is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of this design. The low pressure drop and high pressure rating make it suitable for gravity and pump (in-line) applications and many others. All sensors provide Open Collector NPN frequency output and frequency output on Reed contact via 1-meter 5-wire cable.

 

Features:
  • For highly viscous fluids
  • Value indication, monitoring, transmitting, On/Off control and batch control in combination with different transmitters.

 

Interfacing Device:

 

Reference:

 

Type 8098 – FLOWave SAW flowmeter.

 

Description:

The Type 8098 flowmeter is part of the FLOWave product range. It is based on SAW (Surface Acoustic Waves) technology and is mainly designed for applications with the highest hygienic demands. This is achieved by using: suitable stainless steel materials, a measuring tube free of any wetted parts except for the actual tube, the ideal outer hygienic design. FLOWave offers a range of integrated functions, including the advantages of flexibility, ease of cleaning, compact dimensions, lightweight, easy installation and handling, and is compliant with numerous standards. Optimal measurement results can be achieved with homogeneous liquids, free of air and solid particles. For liquids with high viscosity, an integrated viscosity compensation can be activated. Gas and steam cannot be measured; however, their flow does not have any negative effect on the device or its operation and other liquids flowing through afterwards are measured correctly as before. Beside volume flow, a density measurement optional feature is available. With this option, the mass flow is calculated based on volume flow and density measurements. Special functions derived from further process values (differentiation factor (DF), acoustic transmission factor) offer additional information about the particular liquid in use (for details, see data sheet).

 

Features:
  • No obstacles inside the measuring tube, compact, lightweight and low energy consumption
  • Conforms to hygienic requirements, CIP/SIP compatible
  • Ideal for liquids with low or no conductivity
  • Digital communication, parameterisation via Communicator, display
  • Optional: ATEX/IECEx certification, II 3G/D.

 

Interfacing Devices:

 

Reference: